Airocide PPTTM contains the same Technology Developed for NASA that is used in a variety of Airocide product lines. In addition to serving the floral and perishable preservation and food safety industry the Airocide TM technology has been developed to kill/remove/eliminate airborne pathogenic and non-pathogenic microorganisms in vegetative and spore states (bacteria, mold & fungi, viruses and dust mites), allergens, odors and harmful volatile organic compounds (VOC’s) in air in a variety of commercial, government, and residential market applications including the medical healthcare industry (Airocide is listed as an FDA Class II Medical Device).
We conducted a clinical study of the Airocide PPT airborne pathogen killing technology in the floral cooler inside the facility of Coflores, major cut flower wholesaler in Madrid, Spain. The data supports the hypothesis that airborne mold levels would be dramatically lowered after six days of continuous operation of the Airocide PPT system. The results show an average airborne reduction of 96.01 % inside the cooler in six days.
The floral cooler used in this study was approximately 125 m3 in volume . The test period consisted of six (days of air sampling in April 2005. A baseline air sample was taken in each test location in the cooler on the 12/04/05, without the AirocideTM unit operating. On the same day, one unit Airocide PPT placed inside the floral cooler was turned on and allowed to operate continuously for six days. Active On samples were taken in the same two locations after six days of continuous AirocideTM use on the 18/04/05. All air samples were taken for future comparison.
Air samples were taken with an air sampler Aerotech 6® on 4 x 90 mm plastic petri dishes. Samples were cultured on Sabouraud Chloramphenicol Agar plate by Centro Analitico Pozuelo, Madrid, providing the resulting measured colony forming units (CFU) per cubic meter of air. All agar plates were exposed to 0.5 I/sec. of air and a total measured air volume of 1000 I.
The Table 1 shows airborne reduction inside the cooler in two different points of 98.52% and 93.50%, or an average of 96.01% in six (6) days.
Table 1
One (1) Airocide PPT model ACS-100 is designed to clean the air in enclosed areas up to 1.415m3 (50.000 ft3) under standard operating conditions.*
One (1) Airocide PPT model ACS-50 is designed to clean the air in enclosed areas up to 707 m3 (25.000 ft3) under standard operating conditions.*
*Airocide PPT specification requirements may vary according to the temperature and design of enclosure as well as the sensitivity of its contents to airborne mold, bacteria and ethylene gas. In order to obtain a target airborne pathogen reduction of 90% or greater within 48 hours, we recommend adhering to the defined specifications.